SICK BUILDING SYNDROME: EVALUATION AND MONITORING
Keywords:
Sick Building, Indoor Air Quality, Volatile Organic Pollutants, SensorsAbstract
DOI: https://doi.org/10.46296/ig.v8i15.0266
This article analyzes the issue of indoor air pollution in relation to Sick Building Syndrome, a condition that affects the health and well-being of occupants due to the accumulation of pollutants, including volatile organic compounds (VOCs). The main objective of the study is to identify the most common VOCs found in enclosed spaces, their primary sources of emission, and the most suitable sensors for their detection. The research is based on a systematic literature review, focusing on relevant scientific literature concerning indoor air pollution. Special attention is given to the development and application of monitoring systems based on chemical sensors, considered a key strategy for the detection and control of VOCs in advanced air purification technologies. The results include a list of the VOCs most frequently reported in studies related to Sick Building Syndrome, as well as a selection of sensors specifically designed for the detection of these pollutants. The study concludes that Sick Building Syndrome poses a significant threat to health in indoor environments, highlighting the importance of implementing efficient monitoring systems to improve air quality and prevent adverse health effects among occupants.
Keywords: Sick Building, Indoor Air Quality, Volatile Organic Pollutants, Sensors.
Downloads
References
Agüero Corzo, E. del C., Dávila Morán, R. C., Guanilo Paredes, C. E., Ruiz Nizama, J. L., Velarde Dávila, L., Zapana Diaz, D., & Palomino Quispe, J. F. (2022). Prevalencia del síndrome del edificio enfermo en trabajadores de la industria manufacturera. Boletín de Malariología y Salud Ambiental, 62, 47–54.
Arruda, H., Silva, E. R., Lessa, M., Proença, D., & Bartholo, R. (2022). VOSviewer y Bibliometrix. Journal of the Medical Library Association, 392-395. https://pmc.ncbi.nlm.nih.gov/articles/PMC9782747/
Borges, C. G. R., De León, K. L. A., Rodríguez, J. A. P., & Cedeno, R. A. (2024). Metodología para la planificación estratégica de un parque ecoindustrial en Esmeraldas-Ecuador. Revista de ciencias sociales, 30(2), 274-290. https://dialnet.unirioja.es/servlet/articulo?codigo=9603966
Castell, N., Dauge, F. R., Schneider, P., Vogt, M., Lerner, U., Fishbain, B., Broday, D., & Bartonova, A. (2017). Can commercial low-cost sensor platforms contribute to air quality monitoring and exposure estimates? Environment International, 99, 293–302. https://doi.org/10.1016/j.envint.2016.12.007
Chang, Y., Qu, H., Duan, X., Mu, L., & Reed, M. A. (2016). VOC detection using multimode E-nose composed of bulk acoustic wave resonator and silicon nanowire field effect transistor array. Proceedings of IEEE Sensors, 1–3. https://doi.org/10.1109/ICSENS.2016.7808606
Cincinelli, A., & Martellini, T. (2017). Indoor air quality and health. Int J Environ Res Public Health, 14(11). https://doi.org/10.3390/ijerph14111286
Daza Pérez, M. Á., Martínez Benavides, D. X., & Caro Hernández, P. A. (2015). Contaminación microbiológica del aire al interior y el síndrome del edificio enfermo. Biociencias, 10(2), 37–50. https://dialnet.unirioja.es/servlet/articulo?codigo=5460365
Deng, L., & Deng, Q. (2018). The basic roles of indoor plants in human health and comfort. In Environmental Science and Pollution Research (Vol. 25, Issue 36, pp. 36087–36101). https://doi.org/10.1007/s11356-018-3554-1
Escalona, L., Manganiello, L., López -Fonseca, M., & Vega, C. (2012). Los sensores químicos y su utilidad en el control de gases contaminantes. Revista INGENIERÍA UC, 19(1), 74–88. https://www.redalyc.org/pdf/707/70732261010.pdf
Fierro González, M. D. (2004). Dimensionamiento de un sistema de depuración de aire para eliminar la materia particulada producida en un aserradero [Universidad de Cádiz]. https://rodin.uca.es/xmlui/bitstream/handle/10498/6591/33267455.pdf
Flórez-Martínez, A., Vargas-Flórez, J. O., Perez-Waltero, H. E., & Quintana-Fuentes, L. F. (2020). Análisis de componentes principales utilizando python para identificar clúster asociados a muestras de cacao seco sano e infectado con monilia en Norte de Santander. Aibi revista de investigación, 16-22. https://revistas.udes.edu.co/aibi/article/view/1618/1810
Fu, L., Li, J., & Chen, Y. (2023). An innovative decision making method for air quality monitoring based on big data-assisted artificial intelligence technique. Journal of Innovation & Knowledge, 8(2), 100294. https://doi.org/10.1016/j.jik.2022.100294
Guillén, V. A. M., Pérez-Rodríguez, J. A., & Rodríguez-Borges, C. G. (2025). Análisis de metodologías empleadas en los sistemas de gestión energética y sus indicadores. Revista Científica FINIBUS-Ingeniería, Industria y Arquitectura, 8(15), 103-111. https://publicacionescd.uleam.edu.ec/index.php/finibus/article/view/966
Jabbar, W. A., Subramaniam, T., Ong, A. E., Shu'Ib, M. I., Wu, W., & de Oliveira, M. A. (2022). LoRaWAN-Based IoT System Implementation for Long-Range Outdoor Air Quality Monitoring. Internet of Things, 19, 100540. https://doi.org/10.1016/j.iot.2022.100540
Lozano, J., Suárez, J. I., Meléndez, F., Rodríguez, S., Arroyo, P., Herrero, J. L., & Carmona, P. (2019). Personal electronic systems for citizen measurements of air quality. 2019 5th {Experiment} {International} {Conference} (Exp.at’19), 315–319. https://doi.org/10.1109/EXPAT.2019.8876471
Martínez, A., Luna, G., Calvo, J. M., Valdés-Cruz, A., Magdaleno-Madrigal, V., Fernández-Mas, R., Martínez, D., & Fernández-Guardiola, A. (2002). Análisis espectral (3D) electroencefalográfico de los efectos de la inhalación de compuestos orgánicos volátiles industriales sobre el sueño y la atención en el humano. Salud Mental, 25(4), 56–67.
Matus C., P., & Lucero Ch., R. (2002). Norma primaria de calidad del aire. In Revista Chilena de Enfermedades Respiratorias (Vol. 18, Issue 2, pp. 112–122). https://doi.org/10.4067/s0717-73482002000200006
Ortiz Terán, F., & Haro Haro, B. (2015). Síndrome del edificio enfermo en los bloques académicos de una institución de educación superior. Enfoque UTE, 6(2), 15–24. https://doi.org/10.29019/enfoqueute.v6n2.57
Oyarzún, M. (2010). Contaminación aérea y sus efectos en la salud. In Revista Chilena de Enfermedades Respiratorias (Vol. 26, Issue 1, pp. 16–25). https://www.scielo.cl/pdf/rcher/v26n1/art04.pdf
Park, I., Yang, D., & Kang, K. (2015). Microfabricated and Nanoengineered Chemical Sensors for Air Quality Monitoring System (pp. 141–170). https://doi.org/10.1007/978-94-017-9981-2_6
Pedraza Ortiz, L. J. (2013). La Biodepuración del Aire con Plantas Purificantes y Ornamentales, como Alternativa Ambiental en el Siglo XXI. Journal of Chemical Information and Modeling, 53(9), 1689–1699. https://doi.org/10.1017/CBO9781107415324.004
Saini, J., Dutta, M., & Marques, G. (2021). Sensors for indoor air quality monitoring and assessment through Internet of Things: A systematic review. Environmental Monitoring and Assessment, 193, 66. https://doi.org/10.1007/s10661-020-08781-6
Sánchez Montero, J. M., & Alcántara León, A. R. (2007). Compuestos orgánicos volátiles en el medio ambiente. Monografías de La Real Academia Nacional. https://www.academia.edu/download/50135434/vocs.pdf
Vega, E., Ramírez, O., Sánchez-Reyna, G., Chow, J. C., Watson, J. G., López-Veneroni, D., & Jaimes-Palomera, M. (2022). Volatile organic compounds and carbonyls pollution in Mexico City and an urban industrialized area of Central Mexico. Aerosol and Air Quality Research, 22, Article 210386. https://doi.org/10.4209/aaqr.210386
Younes, J., Volentini, E. D., & Albaca Paraván, C. (2023). Medición y registro de la calidad del aire. Investigación, Desarrollo e Innovación, 44, 26–43. https://www.facet.unt.edu.ar/revistacet/wp-content/uploads/sites/28/2024/02/Revista_CET_N_44_2023_26_43.pdf
Published
How to Cite
Issue
Section
License
Copyright (c) 2025 Scientific Journal INGENIAR: Engineering, Technology and Research

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.












